Sök:

Sökresultat:

2293 Uppsatser om Additional building - Sida 1 av 153

Effekter av nya PBL : En studie av processen från handläggning av bygglovsansökan till slutbesked

It has now passed two years since the new site- and construction law, PBL, went into force. It replaced the previous PBL applicable since 1987, and it involves relatively large changes in many different areas of the construction sector. The ambitions of the new law are for instance to simplify and clarify the legal text, increase efficiency in the permitting processes and improve the quality of construction. To achieve this, a variety of changes was made. Some of the most important are: inserted deadline in the processing of building applications, extended assessment of building applications, revised rules about controlplan and quality manager, a certificate is required to start and end the project, an additional meeting is inserted and the construction management of the municipalities will have to do a mandatory visit at the work scene.

Beckholmen : Varv & Marina

A new shipyard on the island of Beckholmen consisting of a new ship hall and complementary workshops. The program is extended with rentable industrial space for other smaller companies to take advantage of synergies with the yard and to create an active maritime cluster around Beckholmen. By building a marina and a port at the northern shoreline of the island the shipyard can expand their potential customers to non-commercial and larger recreational boats that are becoming increasingly common in Skärgården. The port is also supplemented with a combined naval fuel station, harbor office and a small café. The boat traffic in the region gets a additional stop at the end of the port and act as an additional gateway to Djurgården. Several small retail spaces with direct access to the water is created along the promenade between the port and Djurgården. The shipyard gets a modern and efficient industry building, while the island is made available to the public again, and Beckholmen will hopefully take an equal place in the city's consciousness as it does visually in the inlet to Stockholm..

Alternativa byggsystem för att minska transmissionsförlusterna på miljonprogrammets byggnader

The purpose with this project is to explore and verify three renovating systems for Miljonprogrammet (common expression forbuildings constructed during the years 1965-1975 when over a million houses where built in Sweden) to take measure to thelargely transmission losses of these buildings. Many of the buildings from this period have similar constructions and thereforethe same techniques can be used to renovate several of them. This project only considers the climate scale, although thereare many more factors to concern for to efficient the buildings of Miljonprogrammet.This thesis presents examples of renovations carried out using two of the three renovation systems.The essay presents a reference house of choice on which we apply the three systems and calculate the new U-values,consumption of energy and the investment costs. The new U-values the building is given is matched to the values ofrecommendation for passive houses. Our reference house is a two story apartment building, located in the village ofLammhult, with brick facades at the ends and plaster at the long sides.

Konflikten mellan bevarandekrav och tilläggsisolering : The conflict between conservation requirements and additional insulation

Sweden has formulated ambitious energy goals which signify that by year 2050 the energy usage should be halved. One of the objectives is the reduction of energy usage by 20% by year 2020 and that it should be compared to the usage of energy from 1995. In parallel with increased energy requirements for buildings the demand on housing conservation, by highlighting also buildings from the last 50 years as part of the building heritage, continues to enhance, which in theory means that there is a conflict between these.The law will never be able to point out unique buildings and PBL (planning and building act) is not especially concrete. The National Housing Board has tried to make this more concrete by the new BBR regulations though there are still an enormous variety of interpretations.This report deals with the conflict between conservation requirements and additional insulation of the building envelope and is limited to multi-residential buildings built between the years 1945 and 1975. It is the stock with the greatest energy consumption and that is where the big challenge lies.

Fjärrvärme - ny lokalisering av kraftvärme i Enköping

The municipality of Enköping is presently working out a new layout plan for the town of Enköping and new residences are planned in the harbour area. Because of these plans, the municipal energy company ENA Energi may have to move its location from the harbour to another part of the city.The aim of this degree project is to investigate the possibility of building a new CHP plant in another area of Enköping. The future demand on district heating and infrastructure at the new location have been projected. A new CHP plant has been dimensioned and economic analyses concerning the project have been made.Results show that the future demand of district heating in Enköping will differ a little from the present needs. In 2030, the district heating production is expected to be c.

Lufttäta byggnader

The viscosity of air buildings is a hot topic within the construction performers, which the industry feel they have too little knowledge about. This study is mainly aimed against air density in apartment buildings and airflow measurement. The study consists of a theoretical reference, educational visit, interviews and a survey conducted among construction workers at Magistratshagen in Linkoping.Earlier requirement in terms of air leakage through the climate screen was removed and today there are only energy requirement for a dwelling in Boverkets Building Regulations. The difference between a passive and a typical air tight construction is that the passive house have a maximum requirement of 0.3 l /s m2 of air leakage through the building climate screen. The requirement imposed on passive houses is to minimize the supply of power and energy for heating the building.Air tight constructions have heavy demands on the performance and accuracy of everyone involved with the project. The client must specify their requirements and also be prepared to pay for any additional costs. The architect and building planners have to design the building with regard to air tightness. Finally, the construction workers are required to do a careful work in order to get all the connections in the building air tight.The study suggests that an air tight building is a closed system where no forced ventilation exists. There are no reasons not to build too tight as long as there is a functioning ventilation. In this study the authors ask themselves how an air tight building changes over time. No theoretical information has been found on these changes, but the respondents assume that air density decreases with time. The deterioration is mainly assumed to be caused by construction materials changes over time. The study shows that construction workers knowledge of air tight construction is mixed, which they themselves admit in the survey..

Åtgärdsförslag och känslighetsanalys vid energieffektivisering ur ett fuktsäkert perspektiv : En fallstudie på timmerhuset Sofiedals herrgård

This thesis investigated the possibilities to resume cultivation of an old manor house built of timber and what this would mean from an energy and moisture perspective. The building in this case study is named Sofiedals mansion and was built in 1858 in Valbo 11 kilometers west of Gävle.The structure of the house was documented and used as a starting-point for carrying out calculations focused on energy and moisture aspects. With the help of a number of computer programs and a conducted air tightness test, the buildings energy consumption were calculated and compared with the current building regulations.In addition, the building was analyzed considering energy retrofitting and what it meant for moisture problems. The energy retrofitting consisted of additional insulation, decreasing the buildings permeability through air sealing; window and door replacements. When a building is equipped with natural ventilation it is difficult to know its precise performance and how an energy retrofitting affects it.

Solel till Akademiska sjukhuset : möjlig genererad effekt och solcellers estetiska konsekvenser

Today many buildings and it´s nearby surroundings are designed to achieve some kind of environmental goal.The issue concerning energy consumption is currently at focus and it is relevant that we start increase the share of renewable energy. Solar energy is an infinite resource and should therefore be considered when selecting an energy supplier. Uppsala University hospital is facing major restructuring when parts of the existing buildings will be refurbished and a large new building will be constructed. White Architects have developed a study concerning the new building and for some of the existing buildings on the hospital campus. Uppsala County requires tough energy measures and wants the new building to be classified as an eco-building in Whites following work. The classifications will involve high energy source requirements. This work has been conducted to see if solar power can be envisaged as a supplementary energy source for the University hospital and also to investigate the aesthetic impact of solar cells on the new building.

Kvalitetssäkring vid arbete med fukt i virke

There are many factors in a building project that has to collaborate with one another in order to reach the desired end result, how you work with moisture issues in timber is a very important one. While constructing Varbergs Hospital, the building company Skanska came in contact with the issue of extra high demands on the moisture content in timber. What they requested from us was a moisture program in which you clearly could follow the routines regarding work with moisture in timber. The aim is to use this program as a help during the work, in order to achieve a good result.We have developed this study in addition to the moisture program. The aim is that this study will give you a deeper understanding of the important factors to consider.

Bergkyla och bergvärmeutredning för industrilokalen Rödbergsmyran 5 i Umeå, Västerbotten.

Grubbe Ventilation AB is a sheet metal and ventilation company who provides design, installation, service, and repair of ventilation. The company is expanding their business by building a new facility in Umeå, Västerbotten. The property is designed to be used for both office and industrial work.Grubbe Ventelation AB has not yet decided upon wish system which is to be established to provide the building with heating and cooling. The consulting firm Umeå Projekt Team has therefore been asked to investigate the possibilities to invest in geothermal- heating and cooling.If the investigation of a geothermal heating- and cooling system would provide favorable results it would be a very appropriate alternative that provides energy at low costs and are an environmentally friendly option as the energy comes from stored solar energy in the ground is provided by stored solar energy in the ground.The facility ´s heating and cooling consumptions are calculated in the program BV2 and the result indicate a heating demand of 185 000 kWh per year due to thermal transmittance, transmission losses, heating of warm water and a cooling requirement of 5500 kWh.Three different systems of geothermal heating and cooling were tested in the computer program Energy Earth Design. The results show no difference in the dimensioning of the drill hole if merely heating were to be used or both heating and cooling were to be established.

ISO 9000 och dess funktion i byggbranschen

The purpose with this examination task is to investigate what purchasers and building contractors think of ISO 9000 and the function of it within the building trade.In this material both the purchaser´s and the building contractor´s viewpoints and attitude towards ISO 9000 is being object to an investigation, in order to get a just picture of the function of the quality work within the building trade. The general opinion of ISO 9000 has proven to be positive. During the work with this investigation it appeared that nosystem is that good that it can´t be improved. A widely spread opinion is also that ISO 9000 means a lot of paperwork but also that the certified companies are well organized. Above all the majority demands a standard that is more adjusted to the building trade..

Förbättring av U-värde i träkonstruktion för fönster med Aerogel

When constructing a building, a number of aspects must be harmonized in order for it to fulfill requirements ? a building must fulfill requirements such a load-bearing, conservation of energy and a good indoor environment by means of, among other things, moisture proofing .Moisture problems in buildings can affect health negatively. As we are increasingly staying in indoors, demands on a good indoor environment are higher.This work starts with examining moisture problems in slab-on-ground solutions, and then links the various scenarios to moisture problems in a concrete slab of a real building. The building with moisture problems is located in Årby by in Borlänge and moisture damage was found in the slab at an apartment adjoining wall.By reviewing literature written within the field of moisture problem, making hand calculations and modeling in the program Comsol Multiphysics, judgments are made to find explanations as to why the rise of moisture occurred in the building in Årby by.Generally, the following guidelines may be used to reduce the risk of moisture problems in slab-on-ground constructions:Drying of construction moisture before laying the floor material.Using draining layer beneath the slab, to prevent capillary suction.Using insulation under the slab, partly for comfort and to establish the temperature difference between the ground and the concrete slab.Avoid direct contact between the wood and concrete, due to degradation and fouling smells that normally occurs.If necessary, use additional vapor barrier.In addition to the above, there are various methods for moisture-proof and moisture-monitoring by design or by the method ByggaF suited for the entire construction process various events..

Fuktproblematik i platta på mark : En analys av uppkomsten till fuktproblem

When constructing a building, a number of aspects must be harmonized in order for it to fulfill requirements ? a building must fulfill requirements such a load-bearing, conservation of energy and a good indoor environment by means of, among other things, moisture proofing .Moisture problems in buildings can affect health negatively. As we are increasingly staying in indoors, demands on a good indoor environment are higher.This work starts with examining moisture problems in slab-on-ground solutions, and then links the various scenarios to moisture problems in a concrete slab of a real building. The building with moisture problems is located in Årby by in Borlänge and moisture damage was found in the slab at an apartment adjoining wall.By reviewing literature written within the field of moisture problem, making hand calculations and modeling in the program Comsol Multiphysics, judgments are made to find explanations as to why the rise of moisture occurred in the building in Årby by.Generally, the following guidelines may be used to reduce the risk of moisture problems in slab-on-ground constructions:Drying of construction moisture before laying the floor material.Using draining layer beneath the slab, to prevent capillary suction.Using insulation under the slab, partly for comfort and to establish the temperature difference between the ground and the concrete slab.Avoid direct contact between the wood and concrete, due to degradation and fouling smells that normally occurs.If necessary, use additional vapor barrier.In addition to the above, there are various methods for moisture-proof and moisture-monitoring by design or by the method ByggaF suited for the entire construction process various events..

Ändrad användning av stationshus : fallet Ormaryds station ? ett stationshus med betydande kulturvärden

Acquiring a former station building can mean that the property owners must familiarize themselves with a lot of planning and building regulations. After the new Planning and Building Act code into force in 2011, the responsibility lie on the developer to ensure laws and regulations. Based on the regulatory framework that is available occurs sometimes balance issues, between care requirements and building codes. The station building in Ormaryd was acquired in 2009 by two individuals who intended to accommodate office and retail space in the building. In doing so a new local plan of the area was established, including regulations on how the building could be used. By including road safety and noise, the risk was not considered appropriate to use the station building for housing.

Uppnå användaracceptans genom interaktionsdesign : med CRM-system som applikationsomåde

The purpose of the study was to investigate the use and losses of energy in an existing older building. Another purpose was also to look through various options for heating systems with renewable energy in the building. The aim was to reduce the use and losses of energy. The first step was to study the related electricity bills of the building and also perform measurements and calculations of the building envelope and ventilation. The next step was to find out the possible actions for energy saving by performing measurements and calculations.

1 Nästa sida ->